Page 83 - PHU_User Manual_EN_Rev A
P. 83
OPERATION
PHU 200-140 140 A 280 A 420 A 560 A
PHU 500-60 60 A 60 A 60 A 60 A
PHU 750-40 40 A 80 A 120 A 160 A
PHU 1000-30 30 A 60 A 90 A 120 A
PHU 1500-20 20 A 40 A 60 A 80 A
PHU 80-510 510 A 1020 A 1530 A 2040 A
PHU 200-210 210 A 420 A 630 A 840 A
PHU 500-90 90 A 180 A 270 A 360 A
PHU 750-60 60 A 120A 180 A 240 A
PHU 1000-45 45 A 90 A 135 A 180 A
PHU 1500-30 30 A 60 A 90 A 120 A
Parallel Connection
Parallel Control To operate the power supplies in parallel with the
Connection parallel connectors, connect the Parallel
connectors on the master and slave units as shown
Parallel/Detecting
port in the diagrams below.
DIGITAL I / O Parallel Detection LAN S NC NC S Parallel Control
Analog Interface Parallel Connector
Master SER. NO. LB
1 2 3 4 5 6 7 GND
SENSING
Parallel/ Detecting
Port (Output/ Input)
DIGITAL I / O Parallel Detection LAN S NC NC S Parallel Control
Analog Interface
Slave SER. NO. LB
1 2 3 4 5 6 7 GND
SENSING
DIGITAL I / O Parallel Detection LAN S NC NC S Parallel Control
Analog Interface
Slave SER. NO. LB
1 2 3 4 5 6 7 GND
SENSING
Analog Interface DIGITAL I / O Parallel Detection LAN S NC NC S Parallel Control
Slave SER. NO. LB
1 2 3 4 5 6 7 GND
SENSING
……
Parallel Operation
Master-Slave Before using the power supplies in parallel, the
Configuration master and slave units need to be configured.
83